Account:  - Login  |  Webstore  |  Shopping basket cart
English  |  Français  |  Nederlands

Publication details

Publication CODE Title
IEC 60331-1:2018 RLV (2018-03) TESTS FOR ELECTRIC CABLES UNDER FIRE CONDITIONS - CIRCUIT INTEGRITY - PART 1: TEST METHOD FOR FIRE WITH SHOCK AT A TEMPERATURE OF AT LEAST 830°C FOR CABLES OF RATED VOLTAGE UP TO AND INCLUDING 0,6/1,0 kV AND WITH AN OVERALL DIAMETER EXCEEDING 20 mm
 
Price Excl. VAT Total number of pages, tables and drawings
262.00 € 54.
Description
IEC 60331-1:2018 RLV contains both the official IEC International Standard and its Redline version. The Redline version is not an official document, it is available in English only and provides you with a quick and easy way to compare all the changes between the official IEC Standard and its previous edition.

IEC 60331-1:2018 specifies the test method for cables which are required to maintain circuit integrity when subject to fire and mechanical shock under specified conditions. This document is applicable to cables of rated voltage not exceeding 600 V/1 000 V, including those of rated voltage below 80 V, metallic data and telecom cables and optical fibre cables. It is intended for use when testing cables of greater than 20 mm overall diameter. Cables of smaller diameter are intended to be tested using the apparatus, procedure and requirements of IEC 60331-2. This document includes details for the specific point of failure, continuity checking arrangement, test sample, test procedure and test report relevant to electric power and control cables with rated voltage up to and including 600 V/1 000 V. Details for the specific point of failure, continuity checking arrangement, test sample, test procedure and test report relevant to metallic data and telecom cables and optical fibre cables are not given by IEC 60331-1. Although the scope is restricted to cables with rated voltage up to and including 0,6/1,0 kV, the procedure can be used, with the agreement of the manufacturer and the purchaser, for cables with rated voltage up to and including 1,8/3 (3,3) kV, provided that suitable fuses are used. This second edition cancels and replaces the first edition published in 2009. It constitutes a technical revision. The significant technical changes with respect to the previous edition are as follows:
- extension of the scope to include metallic data and telecom cables and optical fibre cables, although details for the specific point of failure, continuity checking arrangement, test sample, test procedure and test report relevant to metallic data and telecom cables and optical fibre cables are not given by IEC 60331-1;
- improved description of the test environment;
- modified steel test ladder with two extra vertical elements to accommodate the modified testing of single core cables without concentric metal layer and the testing of cables with a bending radius in normal use larger than approximately 400 mm;
- mandatory use of mass flow meters/controllers as the means of controlling accurately the input flow rates of fuel and air to the burner;
- improved description of the information to be included in the test report.
This document has the status of a group safety publication in accordance with IEC Guide 104.
Class  C990  (IEC PUBLICATIONS IEC PUBLICATIONS)
Available files
EN version

Status
Status IEC PUBLICATION
Situation Currently active
Origin
Committee TC 20
ELECTRIC CABLES (HIGH-VOLTAGE AND LOW-VOLTAGE) (Full Committee)(20A/WG16+20B/WG17+20C/WG18)
Responsible Monsieur POLART Jules, Ingénieur
Chaussée de Brunehault, 380
7140  MORLANWELZ
Phone: 064 / 45 16 83
Fax: 064 / 45 16 83
E-mail: jules.polart@ceb-bec.be
Approval
BEC Approval 2018-03-28
ICS-Code (International Standards Classification) 13.220.40 , 29.020 , 29.060.20
NBN Status New
IEC publication date 2018-03-28
IEC stability date 2023-12-31
IEC file modification date 2018-03-28
IEC last modification date 2020-03-24