Publication CODE Title
NBN EN 60079-13:2017 (2017-10) EXPLOSIVE ATMOSPHERES - PART 13: EQUIPMENT PROTECTION BY PRESSURIZED ROOM "P" AND ARTIFICIALLY VENTILATED ROOM "V"
 
Price Excl. VAT Total number of pages, tables and drawings
25.00 € 3.
Description
IEC 60079-13:2017(E) gives requirements for the design, construction, assessment, verification and marking of rooms used to protect internal equipment by pressurization or artificial ventilation or both as applicable when located in an explosive gas atmosphere or combustible dust atmosphere hazardous area with or without an internal source of a flammable gas or vapour. It also includes a room located in a non-hazardous area that has an internal source of release of a flammable gas or vapour. This document deals with rooms that are partially constructed in a manufacturer’s facility and intended to have the final installation completed on-site, as well as rooms that are constructed completely on-site. Rooms partially constructed in a manufacturer’s facility may include third-party verification. For rooms built on-site, this document can be used by plant operators as a guide for assessment of those facilities. This document represents a major technical revision of the requirements for equipment protection by pressurized room "p" and artificially ventilated room "v" and should be considered as introducing all new requirements. This second edition cancels and replaces the first edition published in 2010. This edition constitutes a technical revision.  This edition includes the following significant technical changes with respect to the previous edition: - modification of the title of this document to include artificially ventilated room "v" in addition to pressurized room "p"; - addition of types of protection "pb", "pc", and "vc" and removal of types of protection "px", "py", "pz" and "pv"; - definition of the differences between pressurization and artificial ventilation types of protection; - removal of protection of rooms with an inert gas or a flammable gas from the scope of this document; - addition of an informative annex to include examples of applications where types of protection pressurization or artificial ventilation or pressurization and artificial ventilation can be used and associated guidelines. Additional information regarding the scope of this document can be found in Clause 1.
Class  C
Available files
ATTENTION: Belgian registered standards (NBN EN or NBN HD) are generally only available in English or French. Only the cover page is translated and the document itself is in English or in French.

Very important notice: 98% of the text of the NBN EN 55XXX, NBN EN 6XXXX comes from the IEC text which is NOT included. This text can be ordered here: IEC 60079-13:2017. For the series NBN EN 50XXX, the standards are however complete.

DE version
EN version
FR version
Status
Status Registered trilingual Belgian standard EN or FR or DE
Situation Currently active
Replaces  NBN EN 60079-13:2011
Origin
Committee TC 31
ELECTRICAL APPARATUS FOR POTENTIALLY EXPLOSIVE ATMOSPHERES (Full Committee)
Responsible Ir DELENS Marc
Approval
BEC Approval 2017-06-26
NBN Approval 2017-11-22
Registration 177240
ICS-Code (International Standards Classification) 29.260.20
NBN Status New
Date of ratification (d.o.r.) 2017-06-26
Date of availability (d.a.v.) 2017-10-06
Date of announcement (d.o.a.) 2018-01-06
Date of publication (d.o.p.) 2018-04-06
Date of withdrawal former edition (d.o.w.) 2020-10-06
Correspondences with international standards
Relation International standard Date
is identical to EN 60079-13:2017 2017-10-06
is identical to IEC 60079-13:2017 2017-05-22
Relations to belgian/foreign publications
Type Origin Code Date
Standard Belgium EN 60079-0
Standard Belgium EN 60079-10-1
Standard Belgium EN 60079-29 series
Standard Foreign IEC 60050-426