Publication details
Publication CODE |
Title |
NBN EN 61347-1:2015 (2015-05) |
LAMP CONTROLGEAR - PART 1 : GENERAL AND SAFETY REQUIREMENTS |
|
Price Excl. VAT |
Total number of pages, tables and drawings |
25.00 €
|
6 P.. |
Description
Specifies general and safety requirements for lamp controlgear for use on d.c. supplies up to 250 V and/or a.c. supplies up to 1 000 V at 50 Hz or 60 Hz. This third edition cancels and replaces the second edition published in 2007, Amendment 1:2010 and Amendment 2:2012. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
a) additional marking requirements;
b) additional requirements for creepage distances and clearances:
- for working voltages with operating frequencies up to 30 kHz;
- for working voltages with higher operating frequencies than 30 kHz;
- for impulse and resonance voltages ignition;
- for basic, supplementary and reinforced insulation;
- for insulation between circuits;
- for coated or potted controlgear;
c) modification of definition of ELV and FELV;
d) modification of schematic drawing, showing the different controlgear classification and insulation requirements;
e) scope extension;
f) new Annex A: test to establish whether a conductive part is a live part which may cause an electric shock;
g) new Annex M: creepage distances and clearances for controlgear where a higher degree of availability (impulse withstand category III) may be requested;
h) new Annex Q: example for Up calculation;
i) new Annex P: creepage distances and clearances and distance through isolation (DTI) for lamp controlgear which are protected against pollution by the use of coating or potting;
j) new Annex R: concept of creepage distances and clearances.
This publication is to be read in conjunction with theIEC 61347-2 series
|
Class |
C
|
Available files
ATTENTION: Belgian registered standards (NBN EN or NBN HD) are generally
only available in English or French. Only the cover page is translated
and the document itself is in English or in French.
Very important notice: 98% of the text of the NBN EN 55XXX,
NBN EN 6XXXX comes from the IEC text which is NOT included.
This text can be ordered here:
IEC 61347-1:2015.
For the series NBN EN 50XXX, the standards are however complete.
|
DE version
|
EN version
|
FR version
|
|
Status
Origin
Committee |
TC 34/SC 34C
AUXILIARIES FOR DISCHARGE LAMPS
|
Responsible |
Monsieur DE LEEUW Thierry, Technical Officer
Diamant Building
Bd Auguste Reyers, 80
1030
BRUXELLES
Phone: +32 2 706 85 72
E-mail: thierry.deleeuw@ceb-bec.be
|
Approval
BEC Approval |
2015-03-26 |
NBN Approval |
2015-06-19 |
Belgian Official Journal |
2015-07-03 |
Registration |
157972 |
Numbers identifying the european directives |
2006/95/EC
(Low Voltage Directive (2006/95/EC (Ex 73/23/EC (LVD 5)))
|
ICS-Code (International Standards Classification) |
29.140.99
|
NBN Status |
New |
|
Date of ratification (d.o.r.) |
2015-03-26 |
Date of availability (d.a.v.) |
2015-05-15 |
Date of announcement (d.o.a.) |
2015-06-26 |
Date of publication (d.o.p.) |
2015-12-26 |
Date of withdrawal former edition (d.o.w.) |
2018-03-26 |
|
Correspondences with international standards
Relation |
International standard |
Date |
is identical to |
EN 61347-1:2015
|
2015-05-15 |
is identical to |
IEC 61347-1:2015/ed. 3.0
|
2015-02-19 |
Relations to belgian/foreign publications
Type |
Origin |
Code |
Date |
Standard |
Foreign |
HD 193 S2:1982 |
|
Standard |
Foreign |
HD 243 S12 |
|
Standard |
Foreign |
IEC 60449:1973/A1:1979 |
|
Standard |
Foreign |
ISO 4046-4:2002 |
|
Standard |
Belgium |
NBN C 20-529 |
|
Standard |
Belgium |
NBN EN 60065:2002 |
|
Standard |
Belgium |
NBN EN 60068-2-14:2009 |
|
Standard |
Belgium |
NBN EN 60081 |
|
Standard |
Belgium |
NBN EN 60085:2008 |
|
Standard |
Belgium |
NBN EN 60112:2003 |
|
Standard |
Belgium |
NBN EN 60112:2003/A1:2009 |
|
Standard |
Belgium |
NBN EN 60216 series |
|
Standard |
Belgium |
NBN EN 60317-0-1:2014 |
|
Standard |
Belgium |
NBN EN 60384-14 |
|
Standard |
Belgium |
NBN EN 60598-1:2015 |
|
Standard |
Belgium |
NBN EN 60598-2 series |
|
Standard |
Belgium |
NBN EN 60664-1:2007 |
|
Standard |
Belgium |
NBN EN 60664-4:2006 |
|
Standard |
Belgium |
NBN EN 60691:2003 |
|
Standard |
Belgium |
NBN EN 60695-11-5 |
|
Standard |
Belgium |
NBN EN 60695-2-10 |
|
Standard |
Belgium |
NBN EN 60730-2-3 |
|
Standard |
Belgium |
NBN EN 60901 |
|
Standard |
Belgium |
NBN EN 60921:2004 |
|
Standard |
Belgium |
NBN EN 60921:2004/A1:2006 |
|
Standard |
Belgium |
NBN EN 60923:2005 |
|
Standard |
Belgium |
NBN EN 61180-1:1994 |
|
Standard |
Belgium |
NBN EN 61189-2:2006 |
|
Standard |
Belgium |
NBN EN 61249-2 series |
|
Standard |
Belgium |
NBN EN 61347-2 series |
|
Standard |
Belgium |
NBN EN 61347-2-8 |
|
Standard |
Belgium |
NBN EN 61347-2-9:2013 |
|
Standard |
Belgium |
NBN EN 61558-1:2005 |
|
Standard |
Belgium |
NBN EN 61558-2-16:2009 |
|
Standard |
Belgium |
NBN EN 61558-2-6:2009 |
|
Standard |
Belgium |
NBN IEC 60884-2-4 |
|
Standard |
Belgium |
NBN IEC 60906-3 |
|
|