Account:  - Login  |  Webstore  |  Shopping basket cart
English  |  Français  |  Nederlands

Publication details

Publication CODE Title
NBN EN 50306-4:2020 (2020-03) RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK CABLES HAVING SPECIAL FIRE PERFORMANCE - THIN WALL - PART 4: MULTICORE AND MULTIPAIR SCREENED OR NOT SCREENED SHEATHED CABLES
 
Price Excl. VAT Total number of pages, tables and drawings
54.00 € 31.
Description
This document specifies requirements for, and constructions and dimensions of, multicore and multipair cables rated voltage U0/U: 300/500 V, of the following types: - unscreened, sheathed for either exposed or protected wiring (0,5 mm2 to 2,5 mm2, number of cores from 2 to 48); - screened, sheathed for either exposed or protected wiring (0,5 mm2 to 2,5 mm2, number of cores from 2 to 8); - unscreened, sheathed for either exposed or protected wiring (0,5 mm2 to 1,5 mm2, number of screened pairs of cores from 2 to 7). - screened, sheathed for either exposed or protected wiring (0,5 mm2 to 1,5 mm2, number of unscreened pairs of cores from 2 to 7). All cables have stranded tinned copper conductors, halogen-free, thin wall thickness insulation and standard wall thickness sheath. Cable types are specified for use in exposed situations (Class E), and for protected situations (Class P). They are for use in railway rolling stock as fixed wiring or wiring where limited flexing in operation is encountered. These cables are rated for occasional thermal stresses causing ageing equivalent to continuous operational life at a temperature of 90 °C. For standard cables this is determined by the acceptance test defined in EN 50305, using accelerated long-term (5 000 h) thermal ageing indicating a 110 °C/20 000 h temperature index. If the customer were to require lifetime predictions this would be demonstrated based on the temperature index of the product as supplied by the manufacturer. The maximum temperature for short circuit conditions is 160 °C based on duration of 5 s. Under fire conditions the cables exhibit special performance characteristics in respect of maximum permissible flame propagation (flame spread) and maximum permissible emission of smoke and toxic gases. These requirements are specified to permit the cables to satisfy Hazard Level 3 of EN 45545 1 and EN 45545 2. EN 50306 4:2020 is expected to be used in conjunction with EN 50306-1:2020, General requirements, EN 50306-2:2020, Single core cables, and EN 50306-3:2020, Single core and multicore cables.
Class  C
Available files
ATTENTION: Belgian registered standards (NBN EN or NBN HD) are generally only available in English or French. Only the cover page is translated and the document itself is in English or in French.

FR version
EN version
Status
Status Registered trilingual Belgian standard EN or FR or DE
Situation Currently active
Replaces  NBN EN 50306-4:2002
Origin
Committee CLC/TC 20
Electric cables
Approval
BEC Approval 2019-12-30
NBN Approval 2020-04-29
ICS-Code (International Standards Classification) 13.220.40 , 29.060.20 , 45.060.01
NBN Status New
Date of ratification (d.o.r.) 2019-12-30
Date of availability (d.a.v.) 2020-03-20
Date of announcement (d.o.a.) 2020-06-30
Date of publication (d.o.p.) 2020-12-30
Date of withdrawal former edition (d.o.w.) 2022-12-30
Correspondences with international standards
Relation International standard Date
is identical to EN 50306-4:2020 2020-03-20
Relations to belgian/foreign publications
Type Origin Code Date
Standard Belgium EN 45545-1
Standard Belgium EN 50305:2020
Standard Belgium EN 50306-1:2020
Standard Belgium EN 50306-2:2020
Standard Belgium EN 50306-3:2020
Standard Belgium EN 60332-1-2
Standard Belgium EN 60332-3-24
Standard Belgium EN 60811-1 series
Standard Belgium EN 61034-2
Standard Belgium NBN EN 50264-1:2009