Publication CODE |
Title |
IEC 62439-3:2012 (2012-07) |
INDUSTRIAL COMMUNICATION NETWORKS - HIGH AVAILABILITY AUTOMATION NETWORKS - PART 3: PARALLEL REDUNDANCY PROTOCOL (PRP) AND HIGH-AVAILABILITY SEAMLESS REDUNDANCY (HSR) |
|
Price Excl. VAT |
Total number of pages, tables and drawings |
366.00 €
|
177 P.. |
Description
IEC 62439-3:2012 specifies two redundancy protocols designed to provide seamless recovery in case of single failure of an inter-bridge link or bridge in the network, which are based on the same scheme: duplication of the LAN, resp. duplication of the transmitted information. This second edition cancels and replaces the first edition published in 2010. It constitutes a technical revision. The main changes with respect to the previous edition are:
- specification of the interconnection of PRP and HSR networks;
- introduction of a suffix for PRP frames;
- clarification and modification of specifications to ensure interoperability;
- slackening of the specifications to allow different implementations;
- consideration of clock synchronization according to IEC 61588;
- introduction of test modes to simplify testing and maintenance.
This publication is to be read in conjunction with IEC 62439-1:2010.
|
Class |
C990
(IEC PUBLICATIONS IEC PUBLICATIONS)
|
Committee |
TC 65/SC 65C
DIGITAL COMMUNICATIONS
|
Responsible |
Ir DELENS Marc
|
BEC Approval |
2012-07-05 |
Registration |
127566 |
ICS-Code (International Standards Classification) |
35.100.05
|
NBN Status |
New |
|
IEC publication date |
2012-07-05 |
IEC stability date |
2016-12-31 |
IEC last modification date |
2016-03-31 |
|